Rheumatoid arthritis

Detecting new erosions in rheumatoid arthritis over one year – Radiography and high-resolution computed tomography of finger joints

Joint Bone SpinePublished Diagnostic accuracy study

Authors' conclusion

HR-pQCT identified more than 20 times the number of new erosions, and more than 10 times as many patients with erosive progression than CR.

Study context

Population
Patients with RA with paired high-resolution peripheral quantitative computed tomography (HR-pQCT) and conventional radiography (CR) of the 2nd and 3rd metacarpophalangeal (MCP) joints of the dominant hand at baseline and one-year follow-up
Participants
310 paired image sets
Comparison
CR vs HR-pQCT for detecting new erosions and erosive progression in 2nd and 3rd MCP joints of the dominant hand over one year
Outcome
Number of new erosions in two MCP joints by HR-pQCT vs CR
Follow-up
One year
Methodological detailspaired imaging, HR-pQCT as reference standard
  • Paired imaging
  • HR-pQCT as reference standard

Performance

As reported in the abstract

New erosions

CR

3

events

HR-pQCT

66

events

Further findings

OutcomeValues
Erosions at baselineCR 250 events · HR-pQCT 1864 events
Patients with erosive progression · one yearHR-pQCT 40 events
Diagnostic accuracy of CR for erosive progression (HR-pQCT as reference) · one yearCR sensitivity 2.5% (95% CI: 0.1-13.2%) · specificity 99.3% (95% CI: 97.3-99.9%)

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

Detecting new erosions in rheumatoid arthritis over one year – Radiography and high-resolution computed tomography of finger joints. Joint Bone Spine. Published 14 November 2024. doi:10.1016/j.jbspin.2024.105812

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.