Pediatric rheumatology

Development and validation of a Pediatric Internationally agreed UltraSound Hip synovitis protocol (PIUS-hip), by the PReS imaging working party

Pediatr Rheumatol Online JPublished Diagnostic accuracy study

Authors' conclusion

The Pediatric internationally agreed UltraSound hip synovitis protocol (PIUS-hip) could be limited to one longitudinal scan including B-Mode scoring plus measurement of anterior recess size for maximal sensitivity and specificity for synovitis.

Study context

Population
Consecutive juvenile idiopathic arthritis (JIA) patients with ≥ 1 clinically affected hip joint60 patients
Participants
76 vs 32
Comparison
Musculoskeletal ultrasound (MSUS) of hips with vs without clinical arthritis in JIA
  • Hips with clinical arthritisn = 76
  • Hips without clinical arthritisn = 32reference
Outcome
Sensitivity and specificity of MSUS (pediatric OMERACT B-Mode and power-Doppler scoring) for detection of hip synovitis
Methodological detailsconsecutive patients, interobserver reliability (Fleiss-Kappa)
  • Consecutive patients
  • Interobserver reliability (Fleiss-Kappa)

Performance

As reported in the abstract

B-Mode positivity (grade ≥ 1)
Test or modelValueSensitivitySpecificity
Hips with clinical arthritis97%0.97 (0.93-1.0)0.85 (0.74-0.97)
Hips without clinical arthritis6%

Value

Hips with clinical arthritis97%
Hips without clinical arthritis6%

Sensitivity

Hips with clinical arthritis0.97 (0.93-1.0)
Hips without clinical arthritis— not stated in the abstract

Specificity

Hips with clinical arthritis0.85 (0.74-0.97)
Hips without clinical arthritis— not stated in the abstract

Further findings

OutcomeP value
Anterior recess size (bone to capsula distance)Significantly wider with clinical arthritisp-value 0.001

Anterior recess size cut-off ≥ 7.2 mm for synovitis

AUC
at least 95%
Sensitivity
86%
Specificity
94%

Articular capsula and femoral head cartilage thickness

Did not differ between patients with and without arthritis

Recess size, internal vs external control groups (n = 449)

Comparable in the internal and external control groups

Interobserver reliability of B-Mode (BM) and PD positivity (Fleiss-Kappa)

Kappa (excellent agreement)
0.85

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

Development and validation of a Pediatric Internationally agreed UltraSound Hip synovitis protocol (PIUS-hip), by the PReS imaging working party. Pediatr Rheumatol Online J. Published 13 August 2025. doi:10.1186/s12969-025-01134-y