Gout & crystal arthritis

Agreement Among Multiple Observers on Crystal Identification by Synovial Fluid Microscopy

Arthritis Care Res (Hoboken)Published Cross-sectional study

Authors' conclusion

Compensated polarized microscopy remained consistent in detecting and identifying crystals in synovial fluid, even when examined among multiple observers, confirming its high utility for clinical practice.

Study context

Population
Consecutive synovial fluid samples analysed by compensated polarized microscopy (400×) by 5 observers250 observations · 50 samples
Outcome
Interrater agreement on crystal identification (no crystals, MSU, CPP), Cohen's kappa
Methodological detailsobservational, consecutive synovial fluid sampling, 5 observers blinded to clinical data
  • Observational
  • Consecutive synovial fluid sampling
  • 5 observers blinded to clinical data

Main finding

As reported in the abstract

Interrater agreement (Cohen's kappa)

Overall κ (95% CI 0.64-0.84), good agreement

0.74

Crystal detection κ

0.71

95% CI 0.59–0.82

MSU κ

0.88

95% CI 0.75–1.0

CPP κ

0.69

95% CI 0.56–0.82

Observational data: associations, not effects.

Further findings

Agreement by visualization delay (before vs after 24 hours)

No differences (P = 0.859)

Agreement by expertise in crystal analysis

No differences (P = 0.989)

Ordinary-light observations matching final diagnosis

Matched in 242 of 250 cases
96.8%
  • Most crystal identifications already made by ordinary light

Original publication

Agreement Among Multiple Observers on Crystal Identification by Synovial Fluid Microscopy. Arthritis Care Res (Hoboken). Published 25 November 2022. doi:10.1002/acr.24874

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.